The voltage of the solar installations (also known as photovoltaic or PV installations) increases to reduce cost and improve the efficiency of solar equipment. As a result, it is important to select measuring instruments that support higher voltage measurement to protect the safety of inspection workers. The P2010 enables high voltage measurement up to CAT III 2000 V by simply connecting to a compatible Hioki clamp meter or digital multimeter (DMM).
| Model | Combined accuracy |
| DT4261 | Range 600.0 V: Combined accuracy ±0.8% rdg ±0.2 V Range 2000 V: Combined accuracy ±0.8% rdg ±5 V |
| CM4141-50 CM4371-50 CM4373-50 CM4375-50 |
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V Range 2000 V: Combined accuracy ±1.0% rdg ±3 V |
| DT4281 DT4282 |
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10) Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) |
| DT4252 DT4253 |
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) |
| DT4255 DT4256 |
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10) Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10) |
|
Solar installations are CAT III environments
|
|
Solar installation voltage is increasing
|
|
Safer measurements at solar and PV installationsDC High V Probe Mode: High voltages up to 2000 V can be safely measured when the DC High Voltage Probe P2000 is connected to the compatible Hioki clamp meter or digital multimeter (DMM). |
| Max. input voltage | 2000V DC |
|---|---|
| Maximum rated line-to-ground voltage | 1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V / 2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V |
| Input resistance | 20 MO ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
| Overload protection | 2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L) 600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
| Output terminal | 4 mm banana terminal |
| Operating Temperature | -25°C to 65°C (-13°F to 149°F) |
| Humidity range | -25°C to 40°C (-13°F to 104°F): 80% RH or less (non-condensing) 40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) |
| Storage temperature and humidity range | -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing) |
| Standards | EN 61010 |