Roll over the image to zoom in
₹5,055 (Incl. of all taxes)
₹4,284 + ₹771 GST (18%)
MRP was MRP ₹7,434
Save 32%
3 Business Days
90303100
The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.
| Function | Range | Resolution | Accuracy | |
| AC Volts (40 Hz to 500Hz)1 |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | |
| DC Volts | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 | |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
| Diode Test2 | 2.000 V | 0.001 V | 10 % | |
| Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
| Capacitance3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
| Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | |
| Duty Cycle4 | 1 % to 99 % | 0.1 % | NA | |
| AC Current (40 Hz to 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
| DC Current | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
|
||||
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at dc, 50 Hz or 60 Hz |
− |
| \AC Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − |
| DC Volts | 600 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
|
||||
| Relative Humidity | ||||
| Operating Humidity | Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C |
|||
| Operating Humidity, 40 MΩ Range | ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C | |||
| Altitude | ||||
| Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
| Size (HxWxL) | 142 mm x 69 mm x 28mm | |||
| IP Rating | IEC 60529: IP 40 | |||
| Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 | |||
| Electromagnetic Environment | IEC 61326-1: Portable | |||
| Electromagnetic Compatibility | Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1 | |||
| This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |
| Maximum Voltage Between any Terminal and Earth Ground | 600 V |
|---|---|
| Display (LCD) | 6000 counts, updates 3/sec |
| Battery Type | 2 AAA, NEDA 24A, IEC LR03 |
| Battery Life | 200 hours minimum |
| Temperature Operating | 0 °C to 40 °C |
| Temperature Storage | -30 °C to 60 °C |
| Operating | 2000 Mtr |
| Storage | 12000 Mtr |
| Fuse Protection for Current Inputs | 11A, 1000V Fast Fuse Fluke specified part only |
₹ 10,752Was ₹ 15,812inclusive of GST
Save 32%