Fluke 15B MAX Inherits and continues the classic design of 15B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
| Function | Range | Resolution | Accuracy | |
| 15B MAX | 17B MAX | |||
| AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 | 1.0 % + 3 |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
| DC Volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 | 0.5 % + 3 |
| DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
| AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| DC Current μA2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current A2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
| Temperature 4 | 50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C |
0.1 °C | NA | 2 %+1 °C 2 °C 9 %+2 °C |
| Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency1 (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | 0.1 % + 3 |
| Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
| Continuity Threshold | — | — | 70Ω | 70Ω |
| Backlight | — | — | Yes | Yes |
|
| Input Characteristics | ||||
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 1000 V 1 | >10 MΩ, <100 pF | >60 dB at 50 Hz or 60 Hz | — |
| AC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| DC Volts | 1000 V 1 | >10 MΩ, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
| DC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| 1106 V Hz max |
| General Specifications: | |
| Temperature | Operating 0 °C to 40 °C; Storage -30 °C to 60 °C |
| Relative Humidity | Operating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C |
| Fuse protection for current inputs | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
| Maximum voltage between any Terminal and Earth Ground | 600 V |
|---|---|
| Maximum differential voltage between V and COM terminals | 1000V |
| Display (LCD) | 6000 counts, updates 3/sec |
| Battery Type | 2 AA, IEC LR6 |
| Battery life | 500 hours minimum |
| Ingress Protection | IP40 |
| Electromagnetic Environment | IEC 61326-1: Portable |
| Size (HxWxL) | 183 mm x 91 mm x 49.5 mm |
| Altitude | Operating 2000 Mtr; Storage 12000 Mtr |
| Operating Humidity, 40 M Ohms range | =80 % RH at 10 °C to 30 °C; =70 % RH at 30 °C to 40 °C |
| Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
| Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2 |
Save 32%